PD6830 Pulse Input Rate/Totalizer Instruction

Manual

34

Setting the Time Base (tbase)

The meter calculates rate based on K-Factor and a time base of units per second,
minute, hour, or day.

Press the Enter/Ack button, at any time, to accept a setting or Menu button to exit
without saving changes.

tbase

SETUP

SEC

T BASE

nmin

T BASE

hour

T BASE

Day

T BASE

Setting the Total Conversion Factor (totCF)

Total Conversion Factor is used to convert to a different unit of total display. For
example, to display rate in gallons and total in liters, enter a conversion factor of
3.7854. When rate and total units are the same, the Conversion Factor should be
1.0000.
Press the Enter/Ack button, at any time, to accept a setting or Menu button to exit
without saving changes.

TOTCF

SETUP

3

.7854

TOT CF

d.dddd

TOT CF

Select Conversion

Factor Decimal Point

or

Enter

Conversion

Factor