CUTTING THE VENT TUBES

3

Attach 5" (127 mm) diameter air inlet tube onto the collar of air drop

assembly. Be sure 5" (127 mm) diameter air inlet tube is placed as

far as possible onto the collar of the air drop assembly. Mark the

5" (127 mm) diameter air inlet tube 1 7/16" (36.5 mm) beyond the

mounting surface for the outside wall plate. Remove 5" (127 mm)

diameter air inlet tube from collar of air drop assembly.

4

Attach 3" (76 mm) diameter flue outlet tube onto flue outlet collar

on combustion chamber. Be sure 3" (76 mm) diameter flue outlet

tube is placed as far as possible onto the collar of flue outlet.

Mark the 3" (76 mm) diameter flue outlet tube 2 7/8" (73.0 mm)

beyond the mounting surface for the outside wall plate. Remove

3" (76 mm) diameter flue outlet tube from collar of flue outlet on

combustion chamber.

5

Mark or wrap tape completely around the tubes at the marked points

to help in making a true cut. Do not crimp or enlarge tubes.

MARKER

FLUE OUTLET TUBE

COLLAR OF

FLUE OUTLET

With the furnace installed on wall the 5" (127 mm) diameter air inlet tube and 3" (76 mm) diameter flue outlet tube are to be marked

and cut using the following procedure. After cutting the tubes, each tube should be individually checked for proper length before

installing by fitting in place.