Installation instructions overview – Epson HWDV080DV(N User Manual

Page 14

Advertising
background image

24632-0-0508

Page 14

INSTALLATION INSTRUCTIONS OVERVIEW

Figure 4

Figure 5

Figure 6

Location - All Models
Select a location near the center of the space to be heated. Overflow

heat will circulate through doorways into adjacent rooms.
The furnace is to be located on an outside wall. Locate wall studs

so that wall opening will be located between wall studs. One wall

stud can be used for attachment of inside wall plate. The wall

opening required as shown in Figure 3 is a minimum diameter of

6 1/4" (159 mm). The inside wall plate and the outside wall plate are

large enough to permit a wall opening diameter of 8" (203 mm).

A template is provided in furnace carton for positioning furnace

on the wall. Also, refer to Figure 3 for positioning the furnace on

wall and for locating gas line connection.

Figure 3

For large homes or spread-out floor plans, two or more furnaces

are recommended.
Do not locate furnace where a door could swing over the outer

casing, or where circulation could be retarded by furniture or

cabinets. See Figure 4.
Do not install in a closet, alcove or small hallway where the furnace

could be isolated by closing doors to the heated space. See Figures

5 and 6.
When location is selected, check the walls to make sure there are

no obstructions such as pipes, electric wiring, etc., which would

interfere with the installation of the furnace or vent pipe.

See Page 18, Box 4 for dimensions.