EXTERIOR INSTALLATION OF THE VENTING

Attach 5" (127 mm) diameter air inlet tube onto the collar of air

drop assembly. Attach caulked, outside wall mounting plate into the

5" (127 mm) diameter air inlet tube. Flue outlet tube must be

tightly sealed against the heater and vent cap for safe and proper

operation.

NOTE: Flue outlet tube and air inlet tube should be measured and cut to the proper length from the back of the unit to the outside wall

of the house. There should be little to no venting showing on the outside of the house.

(4) #10 x 2 ½”
SCREWS

Place caulking (not provided) beneath the edge of the outside wall

mounting plate. Use additional caulking to correct uneven wall

surface, such as clapboard.

Position the outside wall mounting plate so that 5" (127 mm)

diameter air inlet tube has a slight downward slope to the outside.

The downward slope is necessary to prevent the entry of rainwater.

Attach outside wall mounting plate to exterior wall with (4) #10

x 2 1/2" (63.5 mm) screws provided.