Reassembly and resealing vent-air intake system – Epson HWDV080DV(N User Manual

Page 26

Advertising
background image

24632-0-0508

Page 26

1

2

3

REASSEMBLY AND RESEALING VENT-AIR INTAKE SYSTEM

When vent-air intake system is removed for servicing the furnace, the following steps will assure proper reassembly and resealing of

the vent-air intake assembly.

Remove old furnace cement from flue outlet collar on combustion

chamber and collar of vent cap. Remove old furnace cement from

both ends of 3" (76 mm) diameter flue outlet tube.

Remove old caulking beneath the edge of the outside wall

mounting plate. Apply new caulking beneath the edge of the

outside wall mounting plate. Use additional caulking to correct

uneven wall surface, such as clapboard.

Attach 5" (127 mm) diameter air inlet tube onto the collar of air

drop assembly. Attach caulked, outside wall mounting plate into

the 5" (127 mm) diameter air inlet tube. Position the outside wall

mounting plate so that 5" (127 mm) diameter air inlet tube has

a slight downward slope to the outside. The downward slope

is necessary to prevent the entry of rainwater. Attach outside

wall mounting plate to exterior wall with (4) #10 x 1" (25 mm)

screws provided.

(4) #10 x 2 ½”
SCREWS