MAINTENANCE INSTRUCTIONS

WARNING:

• Prior to any maintenance operation, it will be necessary to close the gas supply.

• Only qualified personnel are allowed to operate these appliances without the front cabinet installed.

OPERATION

FREQUENCY

FAULTS TO BE

PREVENTED

REMARKS

External cleaning

As required

Dirty exterior

With wet rag or soft cloth. No

qualified persons required

General cleaning of appliances

As required. It is advisable to

perform this operation annually.

Recirculation of suspended

particles in surrounding air,

deposits on the appliance

To be performed by qualified

personnel

Gas leakage control

Only if the equipment has been

moved or if any gas circuit ele-

ment has been changed.

Gas leakage

Check with soapy water solution.

To be performed by qualified

personnel

Cleaning of pilot burner

As required

Clogging of same

To be performed by qualified

personnel

In case of doubt, please check with our Customer Service Department

Use soft dry cloth to wipe cabinet.

Use compressed air to remove dust from around pilot and main burner.

Use a vacuum cleaner or compressed air to clean cap and air inlet ring.

CLEANING BURNER AND PILOT

Cleaning of the burner and pilot may be performed by gently vacuuming loose particles and dust from the burner ports and cleaning the

air intake. Clean the pilot burner with compressed air, pipe cleaner or toothbrush. Do not insert any object (pin, drill bit, etc.) through

pilot orifice. This will destroy the orifice. Any service which requires disconnecting the gas supply line must be performed by a qualified

service person.
Note: It is recommended to shut off pilot in off season.