OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, or loss

of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Keep burner and control

compartment clean.

A) This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B) BEFORE LIGHTING, smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas is

heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire depart-

ment.

C) Use only your hands to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by hand,

do not try to repair it; call a qualified service technician. Force

or attempted repair may result in a fire or explosion.

D) Do not use this appliance if it has been under water. Immedi-

ately call a qualified service technician to inspect the heater

and to replace any part of the control system and any gas

control which has been under water.

NOTE: It is normal for the new heater to give off some odor

the first time it is lit. This is due to final paint curing and to any

undetected oil remaining from the manufacturing process. It is

recommended that you operate your new wall heater for at least

two (2) hours the first time you use it.

ONCE THE UNIT IS IN OPERATION, CHECK ALL GAS

CONNECTIONS WITH A SOAPY WATER SOLUTION.

CHECK THE TEST POINT PRESSURE; IT MUST BE

4" W.C. FOR NATURAL GAS AND 10.0" W.C. FOR LP

GAS.