12

WatchOUT 315DT Installation Manual

Technical Specification

Electrical
Current consumption

30mA at 12 VDC (Stand by)
42mA at 12 VDC (MAX with LED ON)

Voltage requirements

9 -16 VDC

Alarm contacts

24 VDC, 0.1A

AM contacts

24 VDC, 0.1A

Dust output

Open collector 70mA max

Physical
Size: LxWxD

230 x 123 x 124mm (9 x 4.8 x 4.88 in.)

Weight

0.632 Kg (1.4lb)

Environmental
RF immunity

According to EN50130-4

Operating/Storage temperature

-30°C to 60°C (-22°F to 140°F)

* PIR technology is limited in rough environmental conditions.

Ordering Information

Standard Units

Model

Description

WatchOUT 315DT

WatchOUT DT + Swivel

Note

:

Each of the detectors contains a standard swivel and 3 replacement lenses (P/N engraved on the Lens) 1.7m
low installation pet (RL300F), long-range (RL300R) and barrier lens (RL300B).

Accessories Kits

Model

Description

Weight

RA300B

WatchOUT Barrier Swivel Kit

0.1 Kg (0.23 lb)

RA300P

WatchOUT Pole Adaptor Kit

0.25 Kg (0.55 lb)

RA300C

WatchOUT Conduit Adaptor Kit

0.6 Kg (1.27 lb)

RA300HS

WatchOUT Demo Housing

- -

RA300SC

WatchOUT Swivel Metal Conduit Adaptor

1Kg (2.2 lb)

Camera Option

Model

Description

WatchOUT VC1

WatchOUT Camera Cover Adaptor

WatchOUT VC017

WatchOUT Narrow Camera

WatchOUT VC053

WatchOUT Wide Camera

WatchOUT VCPS

WatchOUT Camera 220V Power Supply

WatchOUT VCPS

WatchOUT Camera 120V Power Supply

UL Compliance Section

To comply with UL, note the following:
♦ The unit is intended for outdoor installation where unwanted alarms are tolerable. If not, it

is recommended to connect it to the trouble circuit of a listed compatible control unit.

♦ A dead zone of 5 ft should be considered during installation.
♦ The camera option is not UL listed.
♦ Disclaimer: PET feature has not been tested or verified by UL.
♦ 0.6 power factor inductive load can be used on the relays.
♦ Relay mode is intended to be connected to listed compatible control unit or power supply that provides 4

hours of standby power.

♦ It may be necessary to set detector at maximum sensitivity to achieve maximum distance.
♦ Do not connect the DUST output to a UL listed product.
♦ When the detectors are connected to the BUS of the ProSYS panel, the detectors are to be powered

from either the ProSYS (Version 7.55) panel or a listed compatible burglar alarm power supply that has
an output voltage range that does not exceed 9-16 vdc, has a minimum of 4 hrs. of standby power, and
is suitable for mercantile use.

Only P/N: