WatchOUT 315DT Installation Manual

17

English

Diagnostics

The ProSYS enables you to test parameters that reflect the operation of the detector.

1. From the main user menu press

[4] to access the Maintenance menu.

2. Enter the Installer code (or sub-installer) and press

/

.

3. Press [9] [1] to for the BUS Zones diagnostic menu.

4. Enter the digit of the zone that you want to test and then press

/

. The system will

perform the diagnostics test and a list of test parameters will appear, as indicated in the table
below.

5. Use the keys

/

/

to view the diagnostics test results.

User Menu: 4) Maintenance

→ 9) Diagnostic → 1) BUS Zone

Quick Keys

Parameter

[4][9][1][zzz]

Detector Input Voltage: Display the input voltage of the detector.
PIR 1 Level: PIR channel 1 DC level. Range 0.1v - 4v
PIR 1 Noise Level: PIR channel 1 AC level. Range 0VAC (No noise) - 4VA
PIR 2 Level: PIR channel 2 DC level. Range 0.1v - 4v
PIR 2 Noise Level: PIR channel 2 AC level. Range 0VAC (No noise) - 4VA

MW 1 Level

:

MW channel 1 DC level Range 0.1v - 4v

MW 1 Noise Level

:

MW channel 1 AC level (0VAC (No noise) - 4VAC)

MW 2 Level: MW channel 2 DC level Range 0.1v - 4v
MW 2 Noise Level: MW channel 2 AC level (0VAC (No noise) - 4VAC