14

WatchOUT 315DT Installation Manual

WatchOUT ID: DIP Switches 1 - 5

ID 1 2 3 4

5

ID

1

2 3

4

5

01 OFF OFF OFF OFF OFF

17 OFF OFF OFF OFF ON

02 ON OFF OFF OFF OFF

18 ON OFF OFF OFF ON

03 OFF ON OFF OFF OFF

19 OFF

ON OFF OFF ON

04

ON

ON OFF OFF OFF

20 ON

ON OFF OFF ON

05 OFF OFF ON OFF OFF

21 OFF OFF ON OFF ON

06

ON OFF ON OFF OFF

22 ON OFF ON OFF ON

07 OFF ON

ON OFF OFF

23 OFF

ON

ON OFF ON

08

ON

ON

ON OFF OFF

24 ON

ON

ON OFF ON

09 OFF OFF OFF ON OFF

25 OFF OFF OFF

ON

ON

10

ON OFF OFF ON OFF

26 ON OFF OFF

ON

ON

11 OFF ON OFF ON OFF

27 OFF

ON OFF

ON

ON

12

ON

ON OFF ON OFF

28 ON

ON OFF

ON

ON

13 OFF OFF ON

ON OFF

29 OFF OFF ON

ON

ON

14

ON OFF ON

ON OFF

30 ON OFF ON

ON

ON

15 OFF ON

ON

ON OFF

31 OFF

ON

ON

ON

ON

16

ON

ON

ON

ON OFF

32 ON

ON

ON

ON

ON

ProSYS Programming

The following section describes the additional software programming options, added to the
ProSYS software, that concern the settings of the WatcOUT DT as a BUS detector. Up to 32 BUS
detectors can be added to the system (16 in ProSYS 16) and each of them comes at the expense
of a zone in the system.
It is recommend reading and fully understanding the ProSYS Installation and User Manuals,
before programming the WatchOUT.

Notes:

The WatchOUT is compatible with the ProSYS software Version 4.xx and above.
The WatchOUT can be programmed via the U/D Software from UD Version 1.8 and above.
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring when
connecting the WatchOUT to the BUS.

Adding / Deleting the WatchOUT DT

The WatchOUT is part of a new accessory category, BUS zones. Therefore, Adding/Deleting the
WatchOUT is identical to any other accessory with the following exception:
Each BUS Zone Detector should be assigned to a Regular Zone.

Any BUS detector can be assigned to a physical wired zone or to a virtual zone.

Physical zone: Any zone on the ProSYS PCB (zones 1-8) or on a wired zone expander
(ZE08, ZE16).
Virtual zone: Any zone on a BUS zone expander defined as BZ08 or BZ16.

Notes:

Virtual BUS zones are cost effective. They enable to expand your system zones without adding physical zone
expanders.
The virtual BUS zone expander can be used only for BUS zone detectors.
To add a BUS zone expander select type BZ08 or BZ16 when adding a zone expander (Quick key [7][1][2]).

1. To Add / Delete the WatchOUT DT

1. From the installer menu enter the Add/Delete menu: Quick Key [7][1][9][5] for BUS Zones

detectors.

2. Use the

/

or

/

keys to position the cursor over the BUS Zone

ID number for which you want to assign (or delete) a detector.

Note:

Make sure that the detector's physical ID number is identical to the ID number you select during programming.