WatchOUT 315DT Installation Manual

Changing Back Tamper position

The back tamper is by default secured on the right
side of the internal base (rear view). If you wish to
move it to the left side (rear view), do the following
(Figure 5):
1. Remove tamper screw 1 in order to release the

tamper from position 7.

2. Ensure tamper spring 2 rests over tamper wire

base 4.

3. Ensure plastic tamper bracket 3 rests over both

2 and 4.

4. Secure tamper screw 1 into 3 over position 6.

Figure 5

Left

Side

Tamper

Right

Side

Tamper

3

6

1

2

4

7

5

Notes:

1. Verify that you hear a "Click" when attaching the tamper spring to the wall.
2. For pole installation, the tamper can be moved to the bottom right-hand side of the internal base.

Terminal Wiring

+

-

SET/

UNSET

LEDs

ENABL

AM

YEL

FREE

ALARM

TAMPER

GREEN

FREE

DUST TEST

12VDC

N.C

N.C

WatchOUT DT - PCB

+,-

12 VDC

ALARM

N.C relay, 24VDC , 0.1A

FREE YEL

This terminal is a free pin that can be used to connect wires and EOL resistors

TAMPER

N.C switch, 24VDC , 0.1A

FREE
GREEN

This terminal is a free pin that can be used to connect wires and EOL resistors

AM

Normally closed AM relay output (

24VDC, 0.1A

) indicates Anti Masking alarm or any

trouble in the detector (not including dust/dirty lens).
The Proximity AM enables receiving sabotage alerts before the detector is
damaged or masked, using both microwave channels.

Note:

When DIP8 is defined as Enabled this relay also opens momentarily when a Proximity

AM

attempt occurs

.

LED
ENABLE

Used to remotely control the LEDs when DIP1 is set to ON.
Enable: input is +12V OR no terminal connection
Disable: Connect the input to 0V

DUST

N.O. collector max 70 mA. Indicates that the lens is dirty and requires cleaning.

TEST

Used to perform remote alarm testing to the detector by applying 0 volts to this
terminal.
Success: Alarm relay is momentary opened.
Failure: AM relay is opened

SET/
UNSET

This input enables to control Anti-masking and LEDs operation in accordance to
the system status, Set (Arm) / Unset (Disarm).
While the system is armed this feature prevents an intruder from gaining
knowledge of the detector’s status and disables Anti-masking detection.

System Status

Input Status

AM Relay

LEDs

Set (Arm)

0V

Off

Off

Unset (Disarm)

12V or no connection

On*

On**

* DIP7 is ON (Anti masking enabled)
** DIP1 is ON (LEDs enabled) and LEDs ENABLE input terminal is enabled

(+12V OR no terminal connection)

.