WatchOUT 315DT Installation Manual

7

English

DIP Switch Settings

5 6

7 8

O

1 2

3 4

ON

Factory Defaults

DIP 4: Anti masking Sensitivity

On: High
Off: Low

DIP 5: Detector's optics

On: Barrier / Long range
Off: Wide angle

DIP 6: Red LED /3 LED

On: Red LED only
Off: 3 LEDs

DIP 7: Anti masking operation

On: Enabled
Off: Disabled

DIP 8: Proximity AM

On: Enabled
Off: Disabled

DIP 1: LEDs operation

On: LEDs Enabled
Off: LEDs Disabled

DIP 2-3: Detection Sensitivity

Sensitivity

DIP2

DIP3

Low Off

Off

Mid Off

On

Normal (Default)

On Off

Maximum* On

On

* In maximum sensitivity sway recognition is
disabled to achieve maximum sensitivity

Microwave Adjustment

Adjust Microwave coverage area by using the trimmer on the PCB.

MIN MAX

Walk test

Two minutes after applying power, walk test the protected area to verify
proper operation.
For installations on uneven surfaces slide the PCB inside the internal base to
the appropriate setting according to the desired height (1.0m, 1.5m, 2.2m,
2.7m) as printed on the bottom left corner of the PCB or use the standard
swivel accessory.

For reducing the detection range, slide the PCB up or tilt the swivel
down.

1.00M
1.50M
2.20M
2.70M

PCB

LEDs Display

LED

State

Description

YELLOW

Steady

Indicates PIR detection

Flashing

Indicates Active IR AM (Anti mask) detection

GREEN

Steady Indicates

MW

detection

Flashing

Indicates Proximity AM detection

RED

Steady

Indicates ALARM

Flashing

Indicates malfunctioned communication with ProSYS (BUS
mode only)

All LEDs

Flashing (One
after another)

Unit initialization on power up

Notes:

1. DIP-Switch 1 should be in ON position to enable LED indications.
2. Only one LED is active at any one time. For example, in the case of both PIR and MW detection, either the

steady YELLOW LED or the steady GREEN LED is displayed (the first to detect), followed by the Alarm RED

3. In order to prevent the analysis of detection technologies such as PIR, Microwave, Active IR AM and

Proximity AM, set DIP Switch 6 (SW1) to ON. Only the red LED will be activated.