Changing a rotator bulb, Page 3, Internal wiring / 2 rotators with diamond mirrors – Whelen G1PA User Manual

Page 3: Fig. 4: lamp installation

Advertising
background image

Page 3

WIRE EXIT

HOLE HERE

FRONT OF

LIGHTBAR

4”

CENTER

MOUNT

OPTIONAL

MOUNTING

MOUNTING

HOLES

9¾”

12¾”

BLACK (NEGATIVE) GROUND (-)

RED (POSITIVE) POWER (+)

15 AMP FUSE

(CUSTOMER

SUPPLIED)

SP/ST SWITCH

(CUSTOMER

SUPPLIED)

BLACK

#8 SHEET

METAL

SCREW

HOLE FITS ONTO

MOUNTING BOSS

ON BASE

INTERNAL WIRING / 2 ROTATORS with DIAMOND MIRRORS

WHITE

RED

BLACK

WHITE

RED

#8 SHEET

METAL

SCREW

BLACK

BLACK

HOLE FITS ONTO

MOUNTING BOSS

ON BASE

(+)

Battery

(-)

All customer supplied wires that connect to the positive

terminal of the battery must be sized to supply at least

125% of the maximum operating current and FUSED at the

battery to carry that load. DO NOT USE CIRCUIT

BREAKERS WITH THIS PRODUCT!

Changing a Rotator Bulb:

1.

Remove the 2 dome screws at each end of the lightbar and remove the dome.

2.

After the bulb has completely cooled off, remove the old bulb by removing the
retaining clip then pulling the bulb straight up and unplugging it from its wire. If the
rotators reflector is in the way you may move it by turning the worm gear on the
motor.

WARNING! Turn the reflector by the motor or worm gear only or you will

damage the reflector.

WARNING! Do not touch the glass on the new bulb.

3.

Plug the new bulb into the white wire and insert it into the lamp socket as shown
then replace the retaining clip. Reassemble the lightbar and confirm proper
operation of the rotator.

Fig. 3:
Wiring

Fig. 2:
Mounting Holes

WHITE

W I R E

Retainer Clip must be

fully seated against

lamp body.

Fig. 4:
Lamp Installation