Cas# latency (options are 1 through 6), The write recovery time (options are 2 through 7), This is the dram refresh rate (options are – EVGA force 132-YW-E178 User Manual

Page 67

Advertising
background image

EVGA

56

tCL

: CAS# latency (options are 1 through 6).

tRDC

: RAS#-to-CAS# Delay for Read/Write commands to the same bank (options

are 1 through 7).

tRP

: Row Precharge time. This is the Precharge-to-Active or Auto-to-Refresh of the

same bank (options are 1 through 7).

tRAS

: This is the minimum RAS# active time (options are 1 through 31).

Command Per Clock

: This is the command timing setting on a per clock unit basis

(options are 1T and 2T).

tRRD

: RAS#-to-RAS# delay of different banks (options are 1 through 15).

tRC

: RAS#-to-RAS# or auto refresh time of the same bank (options are 1 through

31).

tWR

: The Write recovery time (options are 2 through 7).

tWTR

: This is the minimum write-to-read delay with the same chip selected (options

are 1 through 10).

tREF

: This is the DRAM refresh rate (options are

Auto

,

7.8uS

, and

3.9uS

).

Parameters

Settings Current Value

Memory Timing Setting

[

Expert

]

tCL (CAS Latency)

[Auto(5)]

5

tRDC

[Auto(7)]

5

tRP

[Auto(7)]

5

tRAS

[Auto(23)]

18

Command Per Clock (CDM)

[Auto(2T)]

1T

** Advanced Memory Settings **

tRRD

[Auto(4)]

3

tRC

[Auto(28)]

22

tWR

[Auto(7)]

5

tWTR

[Auto(10)]

9

tREF

[Auto]

6.1uS

Advertising