background image

Conductor

Mark

MARK

MARK

Getting Acquainted With Your Meter

ALIGNMENT MARKS

Rotary Switch

To turn the meter on and select a function, turn the rotary switch (Figure 4) to a switch
setting.The whole display lights for one second.

Then the meter is ready for use. (If you press and hold down any pushbutton while turn-
ing the meter from OFF to ON, the display remains, lit until the pushbutton is released.)

1) Power Off Position
2) AC Current measurements.
3) AC or DC Voltage.Default is AC voltage.
4) Ohms and Continuity. The continuity buzzer sounds when test value that is

displayed is below 100 counts.

5) Diode and Audible Continuity measurements

.

5

4

)

)

)

3

H

V

2

H

A

1

OFF

)

)

)

Figure 4. Rotary Switch

Figure 3. Alignment Marks

In order to meet the meter accuracy specifications when making a current measurement,
the conductor must be inside the jaws and centered within the indicated marks as much
as possible. (see Figure 3)