Amprobe ACD-330T Clamp-On-Multimeter User Manual

Page 32

Advertising
background image

RESISTANCE / CONTINUITYMEASUREMENT

CAUTION: Make sure that power is removed and all capacitors have been dis-
charged before measuring.

1) Set the rotary switch to ".)))

". OLis displayed.

2) Insert the black test lead to "COM" terminal and red test lead to
" V-

" terminal.

3) Short the test leads together and momentarily press the ZERO button to subtract
test lead resistance from measurement.
4) Touch the test leads to the circuit (Fuse Cartridge or other) and read resistance
value in the display.
5) Press .))) button momentarily to enter continuity function if desired.
6) Repeat steps 3 and 4. The beeper sounds if continuity reading is less than 10.0

.

7) OL(overload) is displayed if the resistance across the input terminals is greater
than the full-scale rating on the range setting of the instrument. Be sure that the
contact between the probes and the circuit is clean. Dirt, oil, paint, rust or other
foreign matter can seriously effect resistance measurements.

Figure 21. Measuring Resistance and Continuity.

FUSE

CARTRIDGE

FUSE

CARTRIDGE

28

Advertising