Amprobe ACD-50NAV ACD-51NAV ACDC-52NAV ACD-53NAV ACD-54NAV Navigator-Clamps User Manual

Page 30

Advertising
background image

24

(4) Frequency

ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV

Function

Range

Accuracy

Frequency

20.00 ~ 99.99Hz

± (0.5% + 3dgt)

20.0 ~ 999.9Hz

0.020 ~ 9.999KHz

Overload protection : 1000 Vrms
600 Arms For ACD-50NAV, ACD-51NAV, ACDC-52NAV
1000 Arms For ACD-53NAV, ACDC-54NAV

Sensitivity :
10~100Vrms for AC 100V range
10~100Arms for AC 100A range ( >400Hz Unspecified)
100~1000Vrms for AC 1000V range
100~600/1000Arms for AC 600A/1000A range ( >400Hz Unspecified)
- Reading will be 0.0 for signals below 10.0 Hz.

(5) Total Harmonic Distortion:

ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV

Function

Range

Accuracy

AC A / AC V

99.9%

± (3.0% + 10dgt)


Harmonic distortion measurement:

ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV

Harmonic order

Range

Accuracy

H01 ~ H12

99.9%

± (5% + 10dgt)

H13 ~ H25

± (10% + 10dgt)

Overload protection: 1000 Vrms
600 Arms For ACD-50NAV, ACD-51NAV, ACDC-52NAV
1000 Arms For ACD-53NAV, ACDC-54NAV

• If ACV<10Vrms or ACA <10Arms, it will display “rdy”.
• If the fundamental frequency out of range 45 ~ 65Hz, it will display

“out.F”.

(6) Inrush Current:

ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV

Function

Range

Accuracy

AC A

99.99A

± (2.5% + 0.2A)

599.9A / 999.9A *

± (2.5% + 5dgt)

* ACD-50NAV, ACD-51NAV, ACDC-52NAV: 599.9A
ACD-53NAV, ACDC-54NAV : 999.9A

Advertising