SPECIFICATIONS
General Specifications

Display :

Voltage functions: 6000 counts LCD display
Power
Ohm & Hz functions: 9999 counts LCD display
ACA clamp-on function: 4000 counts LCD display

Update Rate :

Power function: 2 per second nominal Voltage,
ACA clamp-on & Ohm functions: 2 per second
nominal
Hz function: 1 per second nominal

Polarity :

Automatic

Low Battery :

Below approx. 2.4V

Operating Temperature :

0˚C to 40˚C (32˚ to 104˚F)

Relative Humidity :

Maximum relative humidity 80% for
temperature up to 31˚C (88˚F) decreasing linearly
to 50% relative humidity at 40˚C (104˚F)

Altitude :

Operating below 2000m

Storage Temperature :

-20˚C to 60˚C (-4˚ to 140˚F), < 80% R.H. (with
battery removed)

Temperature Coefficient :

Nominal 0.15 x (specified accuracy)/ ˚C @(0˚C
-18˚C or 28˚C -40˚C) /(32˚ to 64˚F or 82˚ to 104˚F),
or otherwise specified

Sensing :

True RMS sensing

Safety :

Meets IEC61010-1 2nd Ed., EN61010-1 2nd
Ed., UL61010-1 2nd Ed., CAN/CSA C22.2 No.
61010.1-0.92, IEC61010-2-032, EN61010-2-032 &
UL61010B-2-032
Measurement Category : III 600 Volts ac & dc

Transient protection :

6.5kV (1.2/50µs surge)

Pollution degree :

2