True RMS ACV & ACA clamp-on accuracies are specified from 0% to 100% of
range or otherwise specified. Maximum Crest Factor are as specified below,
and with frequency spectrums, besides fundamentals, fall within the meter
specified AC bandwidth for non-sinusoidal waveforms. Fundamentals are
specified at 50Hz and 60Hz.

AC Voltage

Range

Accuracy

50Hz / 60Hz

600.0V

0.5% + 5d

45Hz ~ 500Hz

600.0V

1.5% + 5d

500Hz ~ 3.1kHz

600.0V

2.5% + 5d

CMRR: >60dB @ DC to 60Hz, Rs=1k

Input Impedance: 2M, 30pF nominal

Crest Factor:

< 2 : 1 at full scale & < 4 : 1 at half scale

ACV AutoVATM Threshold: 30VAC (40Hz ~ 500Hz only) nominal

DC Voltage

Range

Accuracy

600.0V

0.5% + 5d

NMRR: >50dB @ 50/60Hz

CMRR: >120dB @ DC, 50/60Hz, Rs=1k

Input Impedance: 2M, 30pF nominal

DCV AutoVATM Threshold: 2.4VDC nominal