Product Description

Indications in Display
(Also refer to display indications):

1)

Symbol for Limit exceeding

2)

Limit: Display at auxillary earth/ Probe-Error
Probe: Probe-Error
Unoise: external voltage

3)

Battery indication

4)

Indication of units, depending on the selection made (8)

5)

Frequency indication
f1=127Hz/ f2=140Hz

6)

Automatic/manual frequency selection

7)

Contact voltage limit

8)

Measurement indication

Control Elements
9)

Connecting sockets for test leads:
Auxillary earth

(H) black

Probe

(S) yellow

Earth probe (ES)

red

Earth

(E) blue

10)

LC Display

11)

Key “UL“ for contact voltage: 50V/ 25V

12)

Key “f1/f2“ for manual frequency selection:
f1=127Hz/ f2=140Hz

13)

Measurement selection switch

14) Key

“Start“

15)

Battery case instrument (back side)

16)

Key “auto/man“ automatic/ manual frequency selection

17)

Key “Display“ for display of:
RE - earth resistance
RH - auxiliary earth resistance
RS - probe resistance
IM - measurement current