Interface

Description

Power Jack

The input power is DC 12V, 2A.
Note: ONLY use package power adapter supplied with the

internet. Otherwise, the product may be damaged.

Network
(RJ-45 LAN
socket)

Connect to PC or Hub/Switch.
For connect to 10Base-T Ethernet or 100Base-TX Fast Ethernet
cabling. This Ethernet port built auto-negotiation protocol can
detect or negotiate the transmission speed of the network
automatically. Please use CAT-5 cable to connect the Network
Camera to a 100Mbps Fast Ethernet network switch or hub.
Note: ONLY use one power source, either from DC or from

802.3af Power over Ethernet.

Line Out
(Green)

Connect a loud speaker to the IP Camera. This is for voice
alerting and two-way audio.

Microphone
Input (Pink)

Connect a microphone to the IP Camera.

Video Output
(BNC)

Connect Video BNC connector to a TV set if necessary (to check
camera viewing angle and focus).

GPIO

The 6 pin terminal block includes 1 input ports and 1 output
ports.

Terminal block for I/O connectors:

Name

Pin

Description

Common

1

Digital output implementation; Pin2 to COM (Pin1) is a
Photo-coupled relay on Normal Open status. External
device can directly connect to the terminals. However the
current that will go through the 2 nodes must not exceed
130mA. An external “Relay” can also be connected to the
terminals as an implementation. In this case, current (or/
and voltage) limitation is specified by the external Relay.

RELAY_NO

2

DGND

3

Connect to GND to activate, or leave floating (or
unconnected) to deactivate.

DIGI Input

4

DGND

5

PIN with a short wire connecting two revert to factory
default settings.

Load default