Electrical Ratings

ƒ

Backplane Current Load: 800 mA @ 5 V DC; 3mA @ 24V DC

ƒ

Operating Temperature: 0 to 60°C (32 to 140°F)

ƒ

Storage Temperature: -40 to 85°C (-40 to 185°F)

ƒ

Shock: 30g Operational; 50g non-operational; Vibration: 5 g from 10 to 150 Hz

ƒ

Relative Humidity 5% to 95% (non-condensing)

ƒ

All phase conductor sizes must be at least 1.3 mm(squared) and all earth ground conductors must be at least
4mm(squared).

Markings

ANSI / ISA

ISA 12.12.01 Class I Division 2, GPs A, B, C, D

CSA/cUL

C22.2 No. 213-1987

CSA CB Certified

IEC61010

ATEX

EN60079-0 Category 3, Zone 2

EN60079-15

243333

Warning: This module is not hot-swappable! Always remove power from the rack before inserting or removing this
module, or damage may result to the module, the processor, or other connected devices.

Battery Life Advisory

All modules in the MVI series use a rechargeable Lithium Vanadium Pentoxide battery to backup the 512K SRAM
memory, real-time clock, and CMOS. The battery should last for the life of the module.
The module must be powered for approximately twenty hours before it becomes fully charged. After it is fully charged,
the battery provides backup power for the CMOS setup and configuration data, the real-time clock, and the 512K
SRAM memory for approximately 21 days.
Before you remove a module from its power source, ensure that the battery within the module is fully charged. A fully
charged battery will hold the BIOS settings (after being removed from its power source) for a limited number of days.
When the battery is fully discharged, the module will revert to the default BIOS settings.

Note: The battery is not user replaceable.

Your Feedback Please

We always want you to feel that you made the right decision to use our products. If you have suggestions, comments,
compliments or complaints about the product, documentation or support, please write or call us.

ProSoft Technology
5201 Truxtun Ave., 3rd Floor
Bakersfield, CA 93309
+1 (661) 716-5100
+1 (661) 716-5101 (Fax)
www.prosoft-technology.com

Copyright © ProSoft Technology, Inc. 2009. All Rights Reserved.

MVI71-MNET User Manual
June 23, 2009

ProSoft Technology ®, ProLinx ®, inRAx ®, ProTalk®, and RadioLinx ® are Registered Trademarks of ProSoft
Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products
and services of, their respective owners.

Advertising
This manual is related to the following products: