E

Control command table

How to read the command table

Command:

Command field (See page 31.)

Direction:

W When the “Parameter” is set in the parameter field (see page 31), the command functions as described

under “Control/Response Contents”.

R The returned value indicated under “Reply” can be obtained by setting “????” or “?

” in the

parameter field (see page 31).

Parameter:

Parameter field (See page 31.)

Reply:

Response (Returned value)

TIPS

• In standby mode, the only command that is used is POWER CONTROL.

• When POWER SAVE MODE is ON, control via LAN is not possible in standby mode.

When POWER SAVE MODE is OFF, control is not possible in standby mode.

Power control/Input mode selection

Function

Command Direction

Parameter

Reply

Control/Response contents

POWER CONTROL

POWR

W

0

Switches to standby mode.

1

Returns from standby mode.

R

0 Standby mode
1 Normal mode

INPUT MODE SELECTION

ITGD

W

0

Toggle change for input mode.

IAVD

WR

1

1 HDMI1

2

2 HDMI2

3

3 HDMI3

4

4 HDMI4

5

5 D-SUB

6

6 MULTIMEDIA (USB port/Internal memory)

PICTURE menu

Function

Command Direction

Parameter

Reply

Control/Response contents

PICTURE MODE

AVMD

W

0

Toggle change for input mode.

1

AV

2

MOVIE

3

GAME

6

VIVID

7

PC

9

sRGB

11

PHOTO

20

Adobe RGB SIM.

R

1 AV
2 MOVIE
3 GAME
6 VIVID
7 PC
9 sRGB

11 PHOTO

20 Adobe RGB SIM.

BRIGHT

VLMP

WR

-16-16

-16-16

CONTRAST

CONT

WR

0-40

0-40

BLACK LEVEL

BLVL

WR

-30-30

-30-30

TINT

TINT

WR

-30-30

-30-30

COLORS

COLR

WR

-30-30

-30-30

SHARPNESS

SHRP

WR

0-20

0-20