A-11 – Epson Y465ss127mo User Manual

Page 247

Advertising
background image

l

All interface conditions are based on TTL level. Both the rise and the

fall times of each signal must be less than 0.2 microseconds.

l

Data transfer must be carried out by observing the ACKNLG or

BUSY signal. Data transfer to this printer can be carried out only

after receipt of the ACKNLG signal or when the level of the BUSY

signal is LOW.

Printing enabled/disabled signals and control conditions
The following table shows the relationship between printing being

enabled or disabled, the on line/off line status, and the receipt of the data

on/off control characters, DC1 or DC3.

ON LINE SLCT IN

ERROR BUSY

(Data

control)

ACKNLG Printing

(Disabled/
enabled)

on line

High

DC1

High

High/Low Pulsed

Enabled

Recv’d

ea. char.

on line

High

DC3

High

High/Low Pulsed

Disabled’

Recv’d

ea. char.

off line

High/Low DC1

Low

High

Not

Disabled

(no effect) (no effect)

generated

*While printing is disabled, character data is being received and

acknowledged so that the printer can look for another DC1 character,

which would allow it to resume printing.

Technical Specifications