Hotkey Beeper Control
The Beeper can be Hotkey toggled On and Off. To toggle the Beeper, do the
following:
1. Invoke HSM (see
2. Press and release
[B].
The Beeper toggles On or Off.
Port Switching Keys
To disable the Port Switching Keys (
[Scroll Lock] [Scroll Lock]
/
[Ctrl]
[Ctrl]
), do the
following:
1. Invoke HSM (see page 24 for details).
2. Press
[X] [Enter]
.
Note:
This procedure is a toggle. To enable the Port Switching keys, repeat
steps 1 and 2.
Firmware Upgrade Mode
To set Firmware Upgrade Mode, do the following:
1. Invoke HSM (see page 24).
2. Key in: upgrade
3. Press
[Enter]
.
The front panel LEDs flash to indicate Firmware Upgrade Mode is in
effect.
Note:
To exit Firmware Upgrade Mode, you must power off the switch.
Restore Default Settings
To reset the CS1942DP / CS1944DP to its default Hotkey settings, do the
following: