21

Measured from top of fireplace opening (in inches)

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

8-3/4

9-1/2

10-1/4

11

11-3/4

12-1/2

13-1/4

14

14-3/4

15-1/2

16-1/4

17

17-3/4

18-1/2

19-1/4

20

30 in. minimum

to ceiling

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).

Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions

Note: All
measurements
in inches.

A 2 in. (51 mm) min.

from fireplace opening
to perpendicular wall

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)

Mantels