7

B. Tempered Glass Specifi cations

Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous
locations such as bathtub enclosures as defi ned by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certifi ed to the
requirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certifi cation Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01 and
02-31917.01).

This statement is in compliance with CPSC 16 CFR
Section 1201.5
“Certifi cation and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”

Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.

C. BTU Specifi cations

MODELS: EDV3633, EDV3633L, EDV3633I, EDV3633IL

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Vented Gas Fireplace

STANDARD: ANSI Z21.88-2005•CSA2.33-2005•UL307B

This product is listed to ANSI standards for “Vented Gas
Fireplace” and applicable sections of “Gas Burning Heat-
ing Appliances for Manufactured Homes and Recreational
Vehicles”, and “Gas Fired Appliances for Use at High
Altitudes”.

E. Non-Combustible Materials Specifi cation

Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC
and UL763 shall be
considered non-combustible materials.

F. Combustible Materials Specifi cation

Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can ig-
nite and burn, whether fl ame proofed or not, or plastered
or unplastered shall be considered combustible materials.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.

When installing above 2000 feet elevation:

• In the USA: Reduce input rate 4% for each 1000 feet

above 2000 feet.

• In CANADA: Reduce input rate 10% for elevations

between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.

Check with your local gas utility to determine proper
orifi ce size.

NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.

1

1

Listing and Code Approvals

A. Appliance Certifi cation

EDV3633 Series

SP

IPI

Input Rate (NG)

20,000

20,000

Orifi ce Size (NG)

0.083

0.083

Input Rate (LP)

20,000

20,000

Orifi ce Size (LP)

0.053

0.053

G. Electrical Codes

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.