Source n :voltage[:level][:immediate][:amplitude, Source – HP E1418A User Manual

Page 92

Advertising
background image

SOURce

n

:VOLTage[:LEVel][:IMMediate][:AMPLitude]

SOURce

n

:VOLTage[:LEVel][:IMMediate][:AMPLitude] <

value

| MIN | MAX | DEF>

immediately outputs the voltage set in value at channel n when the output relay is closed.

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

SOURce

n

keyword

1 to 8 or 1 to 16

1

<

value

>

numeric (float 32) or

discrete

-16 V to +16 V or

MIN | MAX | DEF

0

Comments

•

In the keyword,

SOURce

n, the valid range of n is:

1 to 8 for

E1418A, E1418A Option 002

1 to 16 for

E1418A Option 001, E1418A Option 003.

Values of n outside these ranges will generate an error.

•

The

<

value

>

parameter is a floating point 32-bit number in the range of -16 Volts

to +16 Volts.

MIN

sets -16 Volts.

MAX

sets +16 Volts.

DEF

sets 0 Volts.

•

This command immediately programs the specified voltage on channel n. The
output relay for that channel must be closed for the voltage to appear at the output
terminals.

•

This command generates an error if channel n is in the current output mode.

•

Related Commands:

SOURce

n

:FUNCtion:MODE VOLTage

,

SOURce

n

:VOLTage[:LEVel][:IMMediate][:AMPLitude]?

,

OUTPut

n

[:STATe]

SOURce

Chapter 3

HP E1418A SCPI Command Reference 91

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com