Top vent - vertical termination no elbow, Flex vent – Hearth and Home Technologies Cyclone-BC User Manual

Page 15

Advertising
background image

Heat & Glo • Cyclone-BN, Cyclone-BC • 2073-900 Rev. N • 10/08

15

2. Top Vent - Vertical Termination

No Elbow

Figure 5.6

Figure 5.7

V

T

CAP

V

T

MAX.

40 ft.

Note: Depending on the vent run
an exhaust baffl e may be required
to ensure best fl ame appearance.
See Section 7.B for baffl e installa-
tion instructions.

Flex Vent

The fl ex vent must be supported with the spacing between
support intervals not exceeding 4 feet, with no more than
½ inch sag between supports.

A support is required at each change in venting direction,
and in any location where it is necessary to maintain the
necessary clearance to combustibles. A simple “up and
out” installation requires only enough support to maintain
the necessary clearance to combustibles. However, the
vent attachment point and the fi restop location are con-
sidered to be supports.

3 in. CLEARANCE

TERMINATION

CAP

FLEX-VENT

1 in.

CLEARANCE