Caution, Warning, C. hot surface ignition wiring – Hearth and Home Technologies Cyclone-BC User Manual

Page 31

Advertising
background image

Heat & Glo • Cyclone-BN, Cyclone-BC • 2073-900 Rev. N • 10/08

31

C. Hot Surface Ignition Wiring

This appliance requires a 110 VAC supply to the appliance
terminal block for operation. A wiring diagram is shown in
Figure 10.3.

This appliance is equipped with a 24V valve.

Optional Accessories Requirements

Wiring for optional accessories should be done now to
avoid reconstruction.

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.

• Replace damaged wire with type 105º C rated wire.

• Wire must have high temperature insulation.

WARNING

Figure 10.3 Wiring diagram

ITEM

PART DESCRIPTION

COLOR(S)

1

(M)L1 - (M)F1 - (T) 23 - -120V

Black

2

(FT) BTM-IGN-(T)1- +120V

Black/White

3

(V)1 & (V)3 - GND & (T)4

Blue/Green

4

(V)2 & (V)4 - (M)MV1

Red

5

(M) F2 - (FT) TOP

White

6

(M)S1-IGN

White

7

FEMALE RECEPTACLE PLUG

Black/White/Green

8

REMOTE WITH PIGTAIL - (M)W OPTIONAL

Red

9

(M)R - (M)W - (M)P.SW - REM/WS

Red

1

GROUND

(L1) 120-BLACK

(N) NEUTRAL-WHITE

FAN MOTOR

SENSOR

24 VOLT TRANS

CONTROL MODULE

HOT SURFACE IGNITOR
(HSI)

REMOTE

6

2

7

8

3

5

2

9

4

3

1

Advertising
This manual is related to the following products: