Heat & Glo • Cyclone-BN, Cyclone-BC • 2073-900 Rev. N • 10/08

32

A. Mantel Projections

This appliance is approved to be installed with a clearance
to the ceiling and/or other projections of 12 inch minimum
from the top of the fi replace (see Figure 11.1).

11

11

Finishing

B. Facing Material

Fire Risk.

Finish all edges and fronts to clearances and
specifi cations listed in manual.

• Install combustible materials only up to specified

clearances on top, front and side.

• Seal joints between the fi nished wall and appliance top

and sides using only a 300º F minimum sealant.

Figure 11.1 Clearances to mantels or other combustibles

above appliance

Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause
temperature rise and fi re hazard.

Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.

• Operation of louvers or doors.

• Access for service.

WARNING

WARNING

Figure 11.2 Facing Diagram

0 in.

0 in.

0 in.

1-1/2 in.

12 IN. MIN.

TO CEILING

AND/OR MANTEL

TOP OF

UNIT

Sheetrock or other fi nishing materials can be brought to
within 1-1/2 inch of top of fi replace and to within 0 inches
on the sides and bottom.