9. INSTALLATION OF VIDEO PLOTTER KIT

51

Display pedestal

Front panel

Display pedestal, front view

8. Set the RP Board in the top slot of the pcb card case.
9. Run the cable assembly from the card assy. in front of the GYRO

CONVERTER Board.

10. Plug the connector of the cable assembly in J1 on the RP Board.
11. Fasten the ground wire from the connector at the location shown below.
12. Lead in the AIS cable through the cable clamp at the rear of the display unit.

The armor of the cable should be lying in the clamp at the rear of the
display unit.

INT Board

GYRO

CONVERTER

Board

FRONT

Fasten ground wire from connector to this screw.

Cable assy.

(TOP VIEW)

RP

Board

ARP Board

SPU Board

Route cable between ARP and SPU Boards.

J1

AIS Cable

J4

J456

(Top View)

AIS cable

Cable clamp

Display pedestal, top view