9. INSTALLATION OF VIDEO PLOTTER KIT

52

13. Attach the NH connector assy. (supplied) to the AIS cable and then connect

the NH connector to J4 on the RP Board.

20 mm

(1) Cut shrink tubing

in 20 mm lengths and
slip onto each wire.

(3) Heat shrink

tubing with

soldering iron.

Shrink tubing

(2) Solder connector

to signal cable.

Solder

HOW TO ATTACH NH CONNECTOR

RP BOARD
14P0371A/B

RD-A > 1 >

RD-B > 2 >

GND > 5 >

FA-100 AIS TRANSPONDER
Junction Box

J4

FR-2105 series

Solder

Armor

*

25

26

27

TD-A

TD-B

GNDiso

*

* = Clamp armor
by cable clamp.

Use JIS cable TTYCS-1Q or
equivalent. (See FA-100's
installation manual.)

Pair

Pair

Wiring between RP board and AIS transponder, attaching NH connector

14. Reattach the front panel to the display pedestal.
15. Update the program (if necessary) as follows:

a) Run the PC connection cable between the serial port (D-Sub 9 pin) on the

PC and J456 on the INT Board. See the figure on the previous page for the
location of J456.

1
2
3
4

PC

SERIAL PORT

J456 INT Board (03P9252)

RP-250

TX RS232C

RX RS232C

GND

RS232C RXD
RS232C TXD
GND
N.C.

3
2
5
4
6
7
8

* D-SUB9P connector

* XH4P connector

PC connection