62

4. Conditions Which Display the Alarm for WT and

CPA/TCPA

When both VHW and VBW are input, priority is VBW>VHW.

When only VHW is received, status is as below.

When only VBW is received, status is as below.

When neither VHW or VBW is input, log error is displayed.

STW selected on menu

When data sentence VHW is present, and set, drift and VTG are on or off:

VHW Set, Drift VTG

Mode to be selected AIS alarm display

STW displayed

ON

BT

CPA/TCPA

(Note 3)


ON

OFF


OFF

WT

WT, CPA/TCPA

STW displayed

ON

BT

CPA/TCPA

(Note 3)


ON

OFF


ON

WT None

When data sentence VBW is present, and set, drift and VTG are on or off:

VBW Set, Drift VTG

Mode to be selected AIS alarm display

ON WT

WT, CPA/TCPA


ON

OFF


OFF

WT

WT, CPA/TCPA

ON WT

None


ON

OFF


ON

WT None

SOG selected on menu

When data sentence VHW is present, and set, drift and VTG are on or off:

VHW Set, Drift VTG

Mode to be selected AIS alarm display

ON

BT

CPA/TCPA

SOG displayed


ON

OFF


OFF

WT

WT, CPA/TCPA

(Note 4)

ON

BT

CPA/TCPA

SOG displayed


ON

OFF


ON

WT None

(Note 4)

When data sentence VBW is present, and set, drift and VTG are on or off:

VBW

Set, Drift VTG

Mode to be selected AIS alarm display

ON BT

None


ON

OFF


OFF

BT

None

ON BT

None


ON

OFF


ON

BT None


Notes

1. Because drift is ON.
2. Because of error (no VTG data).
3. STW shown in red. BT is selected because set and drift is input even though setting is
STW.
4. SOG shown in red. SOG is selected, however only VHW is input, therefore SOG cannot

be displayed.