Frymaster FLYMASTER KSCFH18E User Manual

Page 23

Advertising
background image

KSCFH18E COOL ZONE SERIES ELECTRIC FRYERS

CHAPTER 5: PREVENTATIVE MAINTENANCE

5-2

5.4 Periodic/Annual

Frymaster recommends that the fryer be inspected annually by a Factory Authorized Service
Technician for the following checks and adjustments:

Inspect the cabinet inside and out, front and rear for excessive oil build-up and/or oil migration.

Verify that the heating element wires are in good condition and that leads have no visible fraying

or insulation damage and that they are free of oil migration build-up.

Verify that heating elements are in good condition with no carbon/caramelized oil build-up.

Inspect the elements for signs of extensive dry-firing.

Verify that the tilt mechanism is working properly when lifting and lowering elements, and that

the element wires are not binding and/or chafing.

Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s

rating plate.

Verify that the temperature and high-limit probes are properly connected, tightened and

functioning properly, and that mounting hardware and probe guard are present and properly
installed.

Verify that component box and contactor box components (i.e. computer/controller, relays,

interface boards, transformers, contactors, etc.) are in good condition and free from oil migration
build-up and other debris.

Verify that component box and contactor box wiring connections are tight and that wiring is in

good condition.

Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.)

are present and functioning properly.

Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot

insulation is in serviceable condition.

Verify that all wiring harnesses and connections are tight and in good condition.

Built-in Filtration:

Inspect all oil-return and drain lines for leaks and verify that all connections are tight.

Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the

crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof
container and cleaned daily.

Verify that all O-rings and seals (including those on the Power Shower and on quick-disconnect

fittings) are present and in good condition. Replace o-rings and seals if worn or damaged.

Advertising