KSCFH18E COOL ZONE SERIES ELECTRIC FRYERS

CHAPTER 7: TROUBLESHOOTING

7-5

7.2 Fryer Troubleshooting (cont.)



7.2.3

Computer is ON, but the
heating elements fail to
heat.

1. Ensure float safety switch is not stuck in

"down" position. Replace float safety
switch if defective.


2. If computer displays

HELP, check

high-limit thermostat (located on right
back frypot side). Replace if defective.

7.2.4

DRAIN OPEN message
remains after closing drain
valve.


1. Computer was turned OFF while

draining frypot.


2. Close drain valve. Turn computer OFF

and then ON. Computer display will
read ON.


3. Open drain valve for at least 30 seconds.

Computer display will read

DRAIN

OPEN.


4. Close drain valve. Computer display

will read

FILL.


5. Fill frypot with shortening. Press

EXIT/COOL FILTER when ready to
cook.


6. If computer message

DRAIN OPEN

remains after steps 1-4, contact
authorized Frymaster service agent.

a. Drain microswitch may be faulty.

b. Drain circuit may be suspect.

c. Computer may be suspect.

Advertising