KSCFH18E COOL ZONE SERIES ELECTRIC FRYERS

CHAPTER 7: TROUBLESHOOTING

7-6

7.3 Filtration System Troubleshooting

Pump won't

start

y

Return valve not fully open.

y

Tripped circuit breaker.

y

Incorrect or no line voltage.

y

Failed return microswitch.

y

Allow motor to cool for at least 45 minutes and then
press thermal overload switch on motor.

Pump stops

and motor is

cool.

y

Move filter handle to OFF. Allow oil to cool then
empty pan. Verify filter paper is clean and properly
installed. Refill pan and restart process.

Pump starts

and abruptly

stops

y

Reset circuit breaker under control panel.

y

Verify wiring harness is properly connected; a
damaged harness should be replaced by a FASC.

y

Pump is blocked. Call FASC for service.

y

Filter pan suction tube is blocked. Use a thin,
flexible wire to unclog.

y

Motor or 24 VAC transformer failed; call for service.

Pumping is

erratic

y

Verify O-ring on pan outlet is present and in good
condition.

y

Verify paper and screen have been properly
installed.

Oil not being

returned to

frypot

y

Solidified oil or sediment is likely clogging the return
line. Clear line.

After filtering,

fryer does not

operate

properly.

y

Verify drain valve is fully closed.