8 power budget calculations with fiber media, Ower, Udget – GE MULTILINK ML2400 User Manual

Page 69: Alculations, With, Iber, Edia

Advertising
background image

CHAPTER 4: OPERATION

OPERATION

MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

4–5

4.1.8

Power Budget Calculations with Fiber Media

Receiver sensitivity and transmitter power are the parameters necessary to compute the
power budget. To calculate the power budget of different fiber media installations using
MultiLink products, the following equations should be used:

(EQ 4.1)

where: OPB = optical power budget

P

T

= transmitter output power

P

R

= Receiver Sensitivity

The worst case OPB is as follows:

(EQ 4.2)

The worst-case distance is calculated as follows:

(EQ 4.3)

The cable loss in dB/km is defined in the following table:

The following data has been collected to provide guidance to network designers and
installers.

Table 4–1: Cable losses

Cable size

Mode

Cable loss

62.5 / 125

μm

multi-mode

2.8 dB/km

50 / 125

μm

multi-mode

2.8 dB/km

100 / 140

μm

multi-mode

3.3 dB/km

9 / 125

μm

single-mode

0.5 dB/km

0.4 dB/km (LXSC25)

0.25 dB/km (LXSC40)

0.2 dB/km (LXSC70)

OPB

P

t min

(

)

P

R min

(

)

=

OPB

worst

OPB 1dB (LED aging)

1dB (insertion loss)

=

distance

worst

worst-case OPB (in dB)

cable loss (in dB/km)

--------------------------------------------------------

=

Table 4–2: Power budget values for various modules

Module

Speed

Mode

fdx (hdx)

λ

Size

P

T

P

R

OPB

worst

d

worst

OPB

typ

d

typical

A1, A5

10 Mb FL

multi

2 (2) km

850 nm 62.5/125

μm

100/140

μm

50/125

μm

-15.0 dB

-9.5 dB

-19.5 dB

-31 dB

-31 dB

-31 dB

14 dB

19.5 dB

19.5 dB

5.0 km

5.9 km

3.4 km

17 dB

23.5 dB

13.2 dB

6.0 km

7.0 km

4.8 km

A2, A3, A6

100 Mb FX

multi

2 (0.4) km 1300 nm 62.5/125

μm

50/125

μm

-20 dB-

23.5 dB

-31 dB

-31 dB

9.0 dB

5.5 dB

3.0 km

2.0 km

14 dB

12 dB

5.0 km

4.0 km

A8

100 Mb FX

single 18+ (0.4) km 1300 nm

9/125

μm

-15 dB

-31 dB

14 dB

28 km

17.5 dB

35 km

A7, AA, AB

100 Mb FX

multi

2 (0.4) km 1310 nm 62.5/125

μm -19 dB

-31 dB

12 dB

4.0 km

16 dB

5.7 km

AC, AD, AE

100 Mb FX

single

15+ km

1310 nm

9/125

μm

-15 dB

-28 dB

11 dB

22 km

--

--

AF

10 Mb FL

multi

2 (2) km

850 nm 62.5/125

μm

100/140

μm

50/125

μm

-15.0 dB

-9.5 dB

-19.5 dB

-31 dB

-31 dB

-31 dB

14 dB

19.5 dB

9.5 dB

5.0 km

5.9 km

3.4 km

17 dB

23.5 dB

13.5 dB

6.0 km

7.0 km

4.8 km

AH
G7

1000 Mb

multi

0.55 km 1310 nm 62.5/125

μm

50/125

μm

-9.5 dB

-17 dB

5.5 dB

2 km

12.5 dB

4 km

G8

1000 Mb FX

single

10 km

1310 nm

9/125

μm

-9.5 dB

-20 dB

8.5 dB

17 km

10.5 dB

21 km