A l t e rn a t i v e l y, you can receive a database to a new database all in one step, without hav-
ing to manually create a new database first. When the PCI asks if you want to replace the
c u rrent database, select NO. The PCI will then ask you to create a new unit. Select yes
and enter a new database name.

To disconnect from the APS Custom and resume normal activities, select the Disconnect
f rom APS Custom option (see Figure 3-14).

NOTE: The APS Custom may be unavailable for use for five minutes after the

disconnect process. This is normal.

To test for optimum placement of the paging transmitter within a building, use the Pager
Site Survey option. To perf o rm the test, follow the steps below.

1) Select the Connect to APS Custom option from the Remote Access

section of the PCI Main Dialog screen (Figure 3-1).

2) Select the Pager Site Survey option (see Figure 3-14).

3) Enter the CAP code of the pager you wish to use for the test.

4) Identify the pager as alphanumeric or numeric.

5) Enter the pager test interval in seconds (5 - 60 seconds. 30 is re c o m m e n d e d ) .

The system automatically initiates the test and continues to send signals at the specified
i n t e rval to the associated pager until the APS Custom is reset via a power cycle. The APS
Custom will be unavailable for other operations until it is re s e t .

NOTE: The Send Firmware and Send Voice Prompts options are for

Lucent Technologies’ factory use only (see Figure 3-14).