18 bandwidth, Ingress, Egress – MicroNet Technology SP1659P User Manual

Page 56: Andwidth

Advertising
background image

y

Egress: Select the ports that you would like their Restricted Group to set into “Egress” mode. Just tick

the check box beside the port x and valid port is Port 1~26.

3.18 Bandwidth

3.18.1 Ingress

Ingress Bandwidth setting function is used to set up the limit of Ingress bandwidth for each port.

Parameter description:

y

Port No.: Choose the port that you would like this function to work on it. Valid range of the port is 1~26.

y

Rate: Set up the limit of Ingress bandwidth for the port you choose. Incoming traffic will be discarded if

the rate exceeds the value you set up in Data Rate field. Pause frames are also generated if flow

control is enabled. The format of the packet limits to unicast, broadcast and multicast. Valid value of

Port 1~24 ranges from 66~102400, and Port 25~26 ranges from 66~1024000 with the minimum unit of

1. Default value of Port 1~24 is 102400 and Port 25~26 is 1024000.

3.18.2 Egress

Egress Bandwidth Setting function is used to set up the limit of Egress bandwidth for each port.

Parameter description:

55