Port – MicroNet Technology SP1659P User Manual

Page 98

Advertising
background image

10 Normal Enable Normal 0.0 0 0
11 Normal Enable Normal 0.0 0 0
12 Normal Enable Normal 0.0 0 0
13 Normal Enable Normal 0.0 0 0
14 Normal Enable Normal 0.0 0 0
15 Normal Enable Normal 0.0 0 0
16 Normal Enable Normal 0.0 0 0
17 Normal Enable Normal 0.0 0 0
18 Normal Enable Normal 0.0 0 0
19 Normal Enable Normal 0.0 0 0
20 Normal Enable Normal 0.0 0 0
21 Normal Enable Normal 0.0 0 0
22 Normal Enable Normal 0.0 0 0
23 Normal Enable Normal 0.0 0 0
24 Normal Enable Normal 0.0 0 0

SP1659P(poe)#

4.3.18 port

clear counter

Syntax: clear counter

Description: To clear all ports’ counter (include simple and detail port counter) information.

Argument: None

Possible value: None

Example:

SP1659P (port)# clear counter

disable state

Syntax: disable state <range>

Description: To disable the communication capability of the port.

Argument: <range>: syntax 1, 5-7, available from 1 to 26

Possible value: <range>: 1 ~ 26

Example:

SP1659P (port)# disable state 12

enable state

Syntax: enable state <range>

Description: To enable the communication capability of the port.

Argument: <range>: syntax 1, 5-7, available from 1 to 26

Possible value: <range>: 1 ~ 24

Example:

SP1659P (port)# enable state 3-12

set flow-control

Syntax: set flow-control <range> <symmetric | asymmetric>

Description: To set the flow control function of all ports.

Argument:

<range>:port range, syntax 1,5-7, available from 1 to 26

<symmetric>: set its flow control as symmetric

<asymmetric>: set its flow control as asymmetric

Possible value:

97