MicroNet Technology SP1659P User Manual

Page 87

Advertising
background image

set timer

Syntax: set timer <range> <join> <leave> <leaveall>

Description: To set gvrp join time, leave time, and leaveall time for each port.

Argument:

<range> : port range, syntax 1,5-7, available from 1 to 26

<join>: join timer, available from 20 to 100

<leave>: leave timer, available from 60 to 300

<leaveall>: leaveall timer, available from 1000 to 5000

Leave Time must equal double Join Time at least.

Possible value:

<range> : 1 to 26

<join>: 20 to 100

<leave>: 60 to 300

<leaveall>: 1000 to 5000

Example:

SP1659P(gvrp)# set timer 2-8 25 80 2000

show config

Syntax: show config

Description: To display the gvrp configuration.

Argument: none

Possible value: none

Example:

SP1659P(gvrp)# show config
GVRP state: Enable
Port Join Time Leave Time LeaveAll Time Applicant Registrar Restricted
---- --------- ---------- ------------- --------------- --------- ----------
1 20 60 1000 Normal Normal Disable
2 25 80 2000 Normal Normal Disable
3 25 80 2000 Normal Normal Disable
4 25 80 2000 Normal Normal Disable
5 25 80 2000 Normal Normal Disable
6 25 80 2000 Normal Normal Disable
7 25 80 2000 Normal Normal Disable
8 25 80 2000 Normal Normal Disable
:
:
23 20 60 1000 Normal Normal Disable
24 20 60 1000 Normal Normal Disable

25 20 60 1000 Normal Normal Disable

26 20 60 1000 Normal Normal Disable

show counter

Syntax: show counter

Description: Usage: show counter <port>

Argument: <port>: port number

Possible value: <port>: available from 1 to 26

Example:

SP1659P(gvrp)# show counter 2
GVRP Counter port: 2
Counter Name Received Transmitted
-------------------- -------- -----------

86