Diagnostic display, 1800 rpm – Multiquip MQ Power Whisperwatt 60HZ Generator DCA150USJ2 User Manual

Page 29

Advertising
background image

DCa150USJ2 60 hz generator • operation anD partS manUal — rev. #0 (08/22/11) — page 29

diagnOstic display

11. Touch the “Enter Button” to deselect the selected

parameter removing it from the list of parameters being

displayed on the 1-up display.

12. Use the “Arrow Button” to scroll and highlight the

desired parameter that has not been selected for

display.

13. Touch the “Enter Button” to select the highlighted

parameter for inclusion in the Single Engine Parameter

Display.

14. Continue to scroll and select additional parameters for

the custom 1-up Display. Touch the “Menu Button” at

any time to return to the “Custom Setup” menu.

15. Automatic Scan- Selecting the scan function will cause

the 1-Up Display to scroll through the selected set of

parameters one at a time. Use the “Arrow Buttons” to

scroll to the “Automatic Scan” function.

ENGINE SPEED

PERCENT LOAD AT CURRENT RPM
ENGINE OIL PRESSURE
ENGINE COOLANT TEMPERATURE

1

3
2

ENGINE SPEED
PERCENT LOAD AT CURRENT RPM
ENGINE OIL PRESSURE

ENGINE COOLANT TEMPERATURE

2
1

Note that the numbers
now indicate the new order
of display for the parameters.

ENGINE SPEED
PERCENT LOAD AT CURRENT RPM
ENGINE OIL PRESSURE

ENGINE COOLANT TEMPERATURE

2
1

3

USE DEFAULTS
CUSTOM SETUP

AUTOMATIC SCAN OFF

16. Touching the “Enter Button” toggles the “Automatic

Scan” function on.

17. Touching the “Enter Button” again toggles the

“Automatic Scan” function off.

18. Once the “Use Defaults”, “Custom Setup” and

“Automatic Scan” functions have been set touch the

“Menu Button” to return to the main menu.

19. Touch the “Menu Button” to exit the Main menu and

return to the engine parameter display.

USE DEFAULTS
CUSTOM SETUP

AUTOMATIC SCAN ON

USE DEFAULTS
CUSTOM SETUP

AUTOMATIC SCAN OFF

USE DEFAULTS
CUSTOM SETUP

AUTOMATIC SCAN ON

GO TO 1-UP DISPLAY

ENGINE CONF
SETUP 1-UP DISPLAY
SETUP-4-UP DISPLAY
SELECT UNITS

STORED CODES

G

ADJUST BACKLIGHT

COOL

1800 RPM

0

1500

3000

TEMP

ENG RPM

Advertising