Maintenance – Multiquip MQ Power Whisperwatt 60HZ Generator DCA150USJ2 User Manual

Page 55

Advertising
background image

DCa150USJ2 60 hz generator • operation anD partS manUal — rev. #0 (08/22/11) — page 55

CheCK oil level

Check the crankcase oil level prior to each use, or when the

fuel tank is filled. Insufficient oil may cause severe damage

to the engine. Make sure the generator is level. The oil

level must be between the two notches on the dipstick as

shown in Figure 59.

Replacing Oil Filter

„

Remove the old oil filter.

„

Apply a film of oil to the gasket on the new oil filter.

„

Install the new oil filter.

„

After the oil cartridge has been replaced, the engine oil

will drop slightly. Run the engine for a while and check for

leaks before adding more oil if needed. Clean excessive

oil from engine.

FlUShing oUt raDiator anD replaCing

Coolant

„

Open both cocks located at the crankcase side and at

the lower part of the radiator and drain coolant. Open

the radiator cap while draining. Remove the overflow

tank and drain.

„

Check hoses for softening and kinks. Check clamps for

signs of leakage.

„

Tighten both cocks and replace the overflow tank.

„

Replace with coolant as recommended by the engine

manufacturer.

„

Close radiator cap tightly.

„

Flush the radiator by running clean tap water through

radiator until signs of rust and dirt are removed.

DO

NOT clean radiator core with any objects, such as a

screwdriver.

Warning

Allow engine to

cool when flushing out

radiator. Flushing the radiator while hot

could cause serious burns from water or

steam.

raDiator Cleaning

The radiator (Figure 59) should be sprayed (cleaned) with

a high pressure washer when excessive amounts of dirt

and debris have accumulated on the cooling fins or tube.

When using a high pressure washer, stand at least 5 feet

(1.5 meters) away from the radiator to prevent damage to

the fins and tube.

Figure 59. Radiator Cleaning

GENERATOR STORAGE

For long term storage of the generator the following is

recommended:

„

Drain the fuel tank completely. Treat with a fuel stabilizer

if necessary.

„

Completely drain the oil from the crankcase and refill if

necessary with fresh oil.

„

Clean the entire generator, internal and external.

„

Cover the generating set and store in a clean, dry place.

„

Disconnect the battery.

„

Make sure engine coolant is at proper level.

„

If generator is mounted on a trailer, jack trailer up and

place on blocks so tires do not touch the ground or block

and completely remove the tires.

Maintenance

Advertising
This manual is related to the following products: