Programming

Unipro3.5

Rev. 11.00
December 30, 1995

o

Sets the maximum

time to wait for a condition to be
met.*
P

No Effect*

q

No Effect*

r

ILLEGAL! An r

OPCODE must always be followed
by an H OPCODE.
S

No Effect*

T

No Effect*

t

Sets maximum time

to wait for a condition to be met.**
U

Sets maximum time

to wait for a condition to be met.**
Y

Sets the maximum

time allowed to wait for a
condition to be met.*

=

No Effect*

-

No Effect*

*

When a LIMIT

statement follows this
OPCODE it is interpreted
as a NOP.

**

An alarm 93 is displayed and/or
sounded only if the limit statement is
not followed by a branch. If the
condition is not met by the time listed in
the data statement, the unit will display
and/or sound an Alarm #93. If the
alarm need only be acknowledged and
operation is to continue, press Enter
once to silence the alarm and then press
Setpt to skip the LIMIT OPCODE and
resume operation.