Automatic mode – Marathon Computer UNIPRO V3.5 User Manual

Page 88

Advertising
background image

Operation

UNIPRO 3.5

Rev. 11.00
December 30,1995

Either the percent ON time

(time-proportion) or valve position

(position proportion) is displayed

in the SET window. For single

control mode operation this

number is always positive

(0/50/100). The [UP ARROW] and

the [DOWN ARROW] keys

increase or decrease the percent

ON time or the valve position

toward its fully opened or closed

positions by approximately 1%.

This continues for as long as the

key is pressed. The [RIGHT

ARROW] and [LEFT ARROW]

keys force the CONTROL

OUTPUTs to increase or decrease

the percent output by

approximately 10%.

AUTOMATIC MODE

In Automatic Mode the process

variable is displayed in the

PROCESS display, the

SETPOINT is displayed in the

SET display, and control action is

computed based upon the PID

parameters and the input(s).

Pressing and holding the [LEFT

ARROW] key will cause the SET

display to show the control action

as described previously in

"Manual Mode.”