Maintenance and Troubleshooting

Unipro 3.5

Rev. 8.00
November 30, 1995

b.

The jumpers on the events board

are improperly set. Should be configured
for:

-2 pass format
-1200 baud
-Address #1
-Multidrop Mode

c.

There is severe disruption of

communication due to use of wrong cable,
too long a cable run, routing of cable in
non-recommended termination schemes
(i.e. WYE), or improper or missing
termination resistor connections.

Message #93:

Indicates a limit statement has timed out. This must be
interpreted in the particular situation, but if the limit time
specified in the program was realistic, then a flaw in the system
is indicated, or an instrumentation or operator error has
occurred.

Message #94:

Not assigned.

Message #95:

Indicates an illegal ramp, the r OPCODE is not followed by the
H OPCODE in the currently running program.

Message #96:

Indicates that a power failure has occurred and the UNIPRO
started up again in the AUTO RESTART mode as determined
by DIP Switch 5 on Bank 1.