Appendix A: Post Messages

M54E2 System Board Manual

A-1

Message

Possible Cause

Solution

DISKETTE DRIVE A
FAILURE

Drive A failed or is
missing.

Check Setup and cable
connections.

DISKETTE DRIVE B
FAILURE

Drive B failed or is
missing.

Check Setup and cable
connections.

EXTENDED RAM
FAILED AT
OFFSET: nnnn

Extended memory not
working or configured
properly.

Replace defective
memory.

FAILING BITS: nnnn

Memory failure in
System, Extended, or
Shadow memory.

Replace defective
memory.

FIXED DISK X
FAILURE (where X
=0 or 1)

The hard disk is not
configured or working
properly.

Rerun SETUP and check
connections, or replace
hard disk.

FIXED DISK
CONTROLLER
FAILURE

The controller card has
failed.

Check configuration and
connections, or replace
controller card.

INCORRECT DRIVE
A TYPE

Floppy drive A: not set
correctly in Setup.

Run Setup.

INCORRECT DRIVE
B TYPE

Floppy drive A: not set
correctly in Setup.

Run Setup.

INVALID NVRAM
MEDIA TYPE

NVRAM chip is bad.

Requires repair of system
board.

KEYBOARD
ERROR, or
KEYBOARD
CONTROLLER
ERROR

The keyboard or
keyboard controller
failed.

Check connections. You
may have to replace the
keyboard or controller.

KEYBOARD
ERROR nn

A key is jammed or was
held down during boot.

Make sure the keys are
not jammed or dirty.

KEYBOARD
LOCKED

Keyswitch on the front of
the case is locked.

Unlock the keyswitch.

POST Messages

The following table lists the Power On Self Test (POST) messages,
possible causes and solutions.

A