Upgrading the firmware – Metrologic Instruments MS7320 User Manual

Page 43

Advertising
background image

39

U

PGRADING THE

F

IRMWARE


The MS7320 is part of Metrologic's line of scanners with flash upgradeable
firmware. The upgrade process requires, a new firmware file supplied to the
customer by a customer service representative and Metrologic's MetroSet2
software

. A personal computer running Windows 95 or greater with an

available RS232 serial or USB port is required to complete the upgrade.

Do not use the standard cable supplied with Keyboard Wedge or
RS485 MS7320 interface kits for firmware upgrades. If using USB or
RS232 for the upgrade process, the standard USB or RS232 cable
provided with the scanner can be used.


To upgrade the firmware in the MS7320:

1. Plug the scanner into a serial communication port on the host system.

2. Start the MetroSet2 software.

3. Click on the plus sign (+) next to POS Scanners to expand the supported

scanner list.

4. Choose the MS7320 InVista from the list.

5. Click on the Configure InVista/7320 Scanner button.

6. Choose

Flash Utility from the options list located on the left side of the

screen.

7. Click on the Open File button in the Flash Utility window.

8. Locate and open the flash upgrade file supplied by Metrologic.

9. Select the COM port that the scanner is connected to on the host system.

10. Verify the settings listed in the Flash Utility window.

11. Click on the Flash Scanner button to begin the flash upgrade.

12. A message will appear on the screen when the upgrade is complete.





Metrologic's customer service department can be reached at
1-800-ID-METRO or 1-800-436-3876.

MetroSet2 is available for download, at no additional cost, from

http://www.metrologic.com/corporate/download

.