Scanner Pinout Connections

The MS7320 scanner interfaces terminate to 10-pin modular jacks located on the
back of the unit. The serial number label indicates the model number of the
scanner.

Figure 31: Scanner Interface Ports


MS732x-13 OCIA

MS732x-13 IBM 46xx

Pin

Function

Pin

Function

1 Ground

1 Ground

2 NC

2 RS232

Transmit

Output

3 NC

3 RS232

Receive

Input

4 RDATA

4

RTS Output

5 RDATA

Return

5

CTS Input

6 Clock

in

6 DTR

7

Clock out

7

IBM B- (D-)

8

Clock in Return/
Clock out Rtrn

8

IBM A+ (D+)

9 +5VDC

9 +5V

IN

10 Shield

Ground

10 NC